Tecumseh to copeland cross reference Review specifications carefully prior to purchase. %PDF-1. 2°C) 130°F (54. 5 TON SWEAT SCROLL This ready reckoner is intended to serve as a quick reference guide for refrigeration system component sizing. 9. txt) or read online for free. 2°C (-40°F to 10°F) Motor Torque: High Start Torque (HST) Compressor Cooling: Fan Mechanical. The Educational Forums AOP Contractor Locator Map Oct 15, 2015 · The cross reference i've found is a embraco FFI 10HAK to a tecumseh aea4440yxa or a aea3440yxa, The only difference i think between the two tecumsehs are one is low Embraco to tecumseh? Help Copeland Scroll® ZRK5 Compressor Cross Reference Guide TONNAGE ZRK5 Copeland® Bristol Tecumseh Carlyle LG Danfoss 1. : Manufacturer, Model or B/M No. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 General. Height (in) Copeland ARE40C4 Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. 02 11 R290 HMBP • 115V 60Hz Danfoss D, U, L, P, X, S Embraco Tecumseh Danfoss PL, TL, DL, NL Copeland Model Number Tecumseh Model Number Tecumseh Item Number Volts (AC)/Cycles (Hz)-Phase Refrigerant Horsepower BTUH Air Conditioning CR24KQ-PFV AWG5524EXN AW705ET-093-J7 230/208-60-1 R22 2 24,200 models. Weight: 95 LB Displacement (cc): 73. 7 Cross Reference Guide Revision 1 11/02 SEALED UNIT PARTS CO. 5 - 2 Ton %PDF-1. 5T CR14K6-PFV CR14K7-PFV ZR16K5-PFV CR16K6-PFV CR16KQ-PFV CR16K7-PFV CRZ4-0150-PFV CR16KF-PFV CR16K6-PFJ CRZ4-0150-PFJ CR18K6-PFV CR18KQ-PFV CR18K7-PFV CRA1-0150-PFV CR18KF-PFV CR18KH-PFV This document provides a cross-reference of Tecumseh and Embraco compressor models for refrigerants R-134a, R-404A, R-22, and blend refrigerants. 12 ASHRAE -10°F/130°F R R 6. Compressor Replacement Guides and Quick Selects This document is NOT to be used as a drop-in replacement guide. 5 TON COM10032 2. It lists the equivalent Embraco models that can be used to replace specific Tecumseh models for applications including low back pressure (LBP), medium back pressure (MBP), and high back pressure (HBP). ly/2RG See cross reference chart for Tecumseh 33268 and more than 300. 4 %âãÏÓ 13122 0 obj > endobj xref 13122 32 0000000016 00000 n 0000001796 00000 n 0000001960 00000 n 0000006536 00000 n 0000006652 00000 n 0000007721 00000 n 0000008837 00000 n 0000009931 00000 n 0000010985 00000 n 0000011610 00000 n 0000012278 00000 n 0000012378 00000 n 0000012936 00000 n 0000013572 00000 n 0000013664 00000 n 0000014296 00000 n 0000014964 00000 n 0000015065 00000 n Embraco Cross Reference - Tecumseh Note: Cross reference comparisons do not imply that all products compared are exact in reference to form, fit and function. The guide includes model numbers, reference codes, and voltage information to help match the right replacement compressor. If you consent to it, we will u Tecumseh To Copeland Compressor Cross Reference Tecumseh To Copeland Compressor Cross Reference Author: www. Call or email our customer & technical support team for assistance 7 days a week. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 Embraco Cross Reference - Tecumseh Note: Cross reference comparisons do not imply that all products compared are exact in reference to form, fit and function. Evaporating Temp. lge. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 tecumseh_competitive_cross_ref. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 This document provides a cross reference guide for Copeland single phase and three phase compressor models. Repair that worn out compressor? Or replace it with a complete Copeland® brand condensing unit from Emerson Climate Technologies? It’s your reputation. (cm³) Motor Type Torque Performance Connection Line Position Dimension (in) Test Condition Capacity (Btu/h) EER (Btu/Wh) Suction Discharge Height R-134A 25 Secop TL4G L/M/HBP 100 - 115 V 50/60 Hz Oct 15, 2018 · With so many models of compressors for different uses, it is common that the refrigeration technician faces a great question the moment of the exchange: what is the best model to replace equipment which deteriorated? To help with this challenge, we separated the best way of finding the right corresponding model to exchange a compressor. 5 %âãÏÓ 297 0 obj > endobj xref 297 42 0000000016 00000 n 0000001916 00000 n 0000002018 00000 n 0000002529 00000 n 0000002566 00000 n 0000002680 00000 n 0000002792 00000 n 0000004175 00000 n 0000005493 00000 n 0000006670 00000 n 0000007785 00000 n 0000008943 00000 n 0000010161 00000 n 0000010277 00000 n 0000010343 00000 n 0000010366 00000 n 0000010705 00000 n 0000010789 00000 n 6 DANFOSS R-410A PERFORMER BLACK SCROLLS BTU/HR 208-230/1/60 208-230/3/60 460/3/60 Product # Run Cap Product # Product # 29,000 HRH029U1LP6 45/370 Cross reference Nominal HP Tecumseh Danfoss Embraco Old Copeland New Copeland Model Number Btu/h Model Number Btu/h Model Number Btu/h Model Number Compressor Btu/h Model Number Compressor Btu/h LT R-404A -10°F Evap/90°F Ambient 1/4 AE2410Z-AA1AGB 890 M4TL-H025-IAA-*18 AFE08C4E-IAA 860 M6TL-0022-IAA-118 AFE08C4E-IAA 927 Danfoss Light Commercial Refrigeration Compressors 10 FRCC. Check it out!Embraco Toolbox Application (cross-reference AVA2490ZXN - Compressor, hermetic, low temp, 2-1/4 HP, POE, R404A, 208-230/1/60 volt, 7/8" S x 1/2" S Copeland Scroll® ZRK5 Compressor Cross Reference Guide TONNAGE ZRK5 Copeland® Bristol Tecumseh Carlyle LG Danfoss 1. Checkpoint Temperature (°F) ASHRAE ARI LBP LBP Evap. To learn Cross Reference Guide www. com for more information. 8. 4 %âãÏÓ 2157 0 obj > endobj 2194 0 obj >/Filter/FlateDecode/ID[6755E73280C79F4B8B6609BD3ACF5BF2>]/Index[2157 82]/Info 2156 0 R/Length 161/Prev 3945194/Root VSA Model Replaced by VSC Model HP Btu/h Voltage Copeland VSA9514ZNA VSC9515ZNA 2 14,622 208-230/60/1 ZS15K4E-PFV VSA9514ZXG VSC9515ZXG 2 14,499 460/60/3 ZS15K4E-TFD VSC9515ZXH 2 14,499 575/60/3 VSA9514ZXT VSC9515ZXT 2 14,499 200-230/60/3 ZS15K4E-TF5 VSC9519ZNA 2. 4 %âãÏÓ 2329 0 obj > endobj xref 2329 19 0000000016 00000 n 0000002245 00000 n 0000002475 00000 n 0000002916 00000 n 0000003449 00000 n 0000003602 00000 n 0000003804 00000 n 0000004343 00000 n 0000004893 00000 n 0000005348 00000 n 0000005805 00000 n 0000006205 00000 n 0000006678 00000 n 0000007122 00000 n 0000007589 00000 n 0000031654 00000 n 0000040656 00000 n 0000002023 00000 n Copeland Scroll® ZRK5 Compressor Cross Reference Guide TONNAGE ZRK5 Copeland® Bristol Tecumseh Carlyle LG Danfoss 1. NOTE: Cross reference comparisons do not imply that all products compared are exact in reference to form, fit and function. pdf), Text File (. , Voltage, Application-Refrigerant, Btu/h Rating, Tecumseh Model Your customers are buying Tecumseh FHP products from another wholesaler. txt) or view presentation slides online. Mounting and tubing connections are likely to differ from the original compressor. Looking for flow controls for A/C & Refrigeration? Use our White-Rodgers selector. Ask your wholesaler or visit EmersonClimateContractor. We use cookies to personalise ads and to analyse our traffic. 051. : Amb See cross reference chart for Tecumseh 35066 and more than 300. 2 13. 5T ZP14K5E-PFV ZP16K5E-PFJ ZP16K5E-PFV ZP16K3E copeland-service-cr-compresso-cross-reference-manual-guide-en-us-1569036. pdf - Free download as PDF File (. TPA9421YXA - Compressor, hermetic, high temp, 1/3 HP, POE, R134a, 5. ModelTecumseh CAE2420Z Any info is appreciated It's on a superior 1 door reach in freezer Model FR-23 I'm faintly remembering replacing a comp on one of these under warranty and norlake had me use an ASE24C3E-IAA Copeland ® condensing unit Tecumseh AEA4440AXAXB 1-115 AEA4440AXA R-12 1/3 17. Key features include: Product Specifications for Compressors, Condensing Units, and More; Preliminary and Obsolete Data; Competitor and Obsolete Cross-Reference Data ; Library of Marketing and Application Engineering Bulletins %PDF-1. : Liq. 5T ZP14K5E-PFV ZP16K5E-PFJ ZP16K5E-PFV ZP16K3E Embraco Cross Reference - Copeland Note: Cross reference comparisons do not imply that all products compared are exact in reference to form, fit and function. Condensing Unit Cross Reference Copeland to Tecumseh. Check element length. Copeland Scroll ZRK5 Compressor Cross Reference Guide. 5T ZR54K5-PFV H21C533 SRD510HC SRA054K HRM051U1 H21R543ABC XRD510HA HRM054U1 H22C563 XRD510HE H23R513ABC XRD510HU H23R543ABC XRD540HA Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. The cross-reference is offered as a tool to help identify potential replacement options based on performance. Refrigeration compressors and condensing units danfoss com. PDF . , INC. Copeland Scroll 4-9 HP ZF*K4 for Refrigeration Copeland Scroll™ ZRK5 Compressor Cross Reference Guide Code HPhaseVolts PFV 01208/230 PF 0125 TF5 03200/230 TFD 0340 TFE 0355 TF 03380 4. EMPTY SPACES There is no equivalent model . Copeland Scroll 4-9 HP ZF*K4 for Refrigeration Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Code Hz-Phase-Volts PFV 60-1-208/230 PFJ 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-575 TF7 60-3-380 Copeland™ ZPK5 Single Phase Compressor Models Tonnage ZPK5 Preferred Wholesale Model ZPK5 Special Order Model ZPK3 ZPKC CP8 1. 2 | LG Scroll LG Scroll R22, R410a Compressor Copeland Copeland. 2230 Landmark Place Allenwood, NJ 08720 SUPCO Mars WR / RBM Copeland Tecumseh Tecumseh Relay and Overload Kit Reference August 19, 2010 Relay Kit Part No Overload Kit Part No Compressor Model Old Relay Kit Part No Old Overload Kit Part No AB5513G, H K71-19 AB5515G, H K71-19 AB5517G, H K71-19 AB5519F, G, H K71-19 AEA0418AXA K90-11 AEA1336AXA K90-01 P83541 AEA1338YXA K71-05 K90-03 P83628 AEA1343AXA K71-05 P82654 K90-02 P83480 Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Code H-Phase-Volts PFV 60-1-208/230 PF 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-55 TF 60-3-380 UltraTech™ Copeland™ ZPSK5 UltraTech™ Single Phase Compressor Models Copeland™ ZPSK5 UltraTech™ Three Phase Compressor Models Tonnage ZPSK5 Preferred Wholesale Model ZPSK4 2T Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. Range :-40°C to -12. Use with 92301 auxiliary contact kit. It lists Copeland compressor models and their equivalents in various tonnages from 1. (cm³) Motor Type Torque Performance Connection Line Position Dimension (in) Test Condition Capacity (Btu/h) EER (Btu/Wh) Suction Discharge Height R-134A 25 Secop TL4G L/M/HBP 100 - 115 V 50/60 Hz contact Tecumseh Products Company. embraco Western Component Sales. 5 X 4 EER EMBRACO TO TECUMSEH COMPRESSOR CROSS REFERENCE Cross Reference: Alliance-Copeland: R410-A Scroll Compressors. 5T ZR16K5-PFV ZR16K4-PFV H2EB153ABC AWJ5517EXN ZR18K5-PFV ZR18K4-PFV H20J193ABC AW5519E H21J173ABC AW5519F H21J17BABC AW5519G H21J193ABC AWA5519EXD H21J19BABC AWB5519EXD AWC5519EXD Single Phase 1. 000 other air filters. Embraco Cross Reference Danfoss United Components. PK. 5T ZR54K5-PFV H21C533 SRD510HC SRA054K HRM051U1 H21R543ABC XRD510HA HRM054U1 H22C563 XRD510HE H23R513ABC XRD510HU H23R543ABC XRD540HA We are using cookies to give you the best experience on our site. English . 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Code H-Phase-Volts PFV 60-1-208/230 PF 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-55 TF 60-3-380 UltraTech™ Copeland™ ZPSK5 UltraTech™ Single Phase Compressor Models Copeland™ ZPSK5 UltraTech™ Three Phase Compressor Models Tonnage ZPSK5 Preferred Wholesale Model ZPSK4 2T Tecumseh Relay and Overload Kit Reference August 19, 2010 Relay Kit Part No Overload Kit Part No Compressor Model Old Relay Kit Part No Old Overload Kit Part No AB5513G, H K71-19 AB5515G, H K71-19 AB5517G, H K71-19 AB5519F, G, H K71-19 AEA0418AXA K90-11 AEA1336AXA K90-01 P83541 AEA1338YXA K71-05 K90-03 P83628 AEA1343AXA K71-05 P82654 K90-02 P83480 Copeland offers the most comprehensive product information in the industry via our online product information (OPI) tool. 5 19,501 208-230/60/1 ZS19K4E-PFV VSA9517ZXG VSC9519ZXG 2. Apr 9, 2021 · Tecumseh, Copeland, Compressor, Cross, Reference, P12FW, Compressor, R-12, 1/3HP, 230V, HMBP, ACC-ELECTROLUX, CUBIGEL/HUAYI This website uses cookies to ensure you get the best experience on our website. We are using cookies to give you the best experience on our site. edu-2024-11-20-01-57-01 Subject: Tecumseh To Copeland Compressor Cross Reference Keywords: tecumseh,to,copeland,compressor,cross,reference Created Date: 11/20/2024 1:57:01 AM Learn how to use the OPI to search for a Copeland replacement from a competitor condensing unit with model comparison. edu-2024-11-14-03-34-52 Subject: Tecumseh To Copeland Compressor Cross Reference Author: mj. (*) In some applications start capacitor usage is mandatory. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Log in Products; Product configurators; Tools; Documentation We are using cookies to give you the best experience on our site. 9 Copeland MBFS-0033-IAA-103 ARE37C3-IAA-103 R-12 13. 5. 0 EER, 115/1/60 volt, 3/8" S x 1/4" S Copeland Scroll™ ZRK5 Compressor Cross Reference Guide Code HPhaseVolts PFV 01208/230 PF 0125 TF5 03200/230 TFD 0340 TFE 0355 TF 03380 4. CROSS REFERENCE AE2 to Legacy AE/TP Compressor Models Legacy AE/TP to AE2 Compressor Models AE2 Model AE2 Item Number / BOM Conn discharge x suction (ODF) Replaces AE and TP Compressor Models Model Current Item Number / BOM Copeland™ AF Compressor for Low Temperature Refrigeration Click to view our Accessibility Policy and contact us with accessibility-related issues Skip to Navigation Copeland Multi-Refrigerant Condensing Units with Copeland Scroll™ Compressors (FFAP/FFWP/FPAK) Tecumseh Online Cross-Reference Tool. Copeland Scroll® ZRK5 Compressor Cross Reference Guide TONNAGE ZRK5 Copeland® Bristol Tecumseh Carlyle LG Danfoss 1. Use with (2) 92301 auxiliary contact kits. Replace or repair? It’s a tough choice. com Are you a European Customer? Please use the TParts Finder Tool for the most accurate, up-to-date replacement parts information. 5T ZR54K5-PFV H21C533 SRD510HC SRA054K HRM051U1 H21R543ABC XRD510HA HRM054U1 H22C563 XRD510HE H23R513ABC XRD510HU H23R543ABC XRD540HA Nov 23, 2024 · COMPRESSOR CROSS REFERENCE dms hvacpartners com. P. N/A 6. Nov 25, 2024 · Copeland Service CR Compressor Cross Reference Guide May 4th, 2018 - Legend Voltage Code 60 1 208 230 60 1 265 60 3 200 230 60 3 460 60 3 575 Copeland® Service CR Compressor Cross Reference Guide Single Phase CR6 5T BRISTOL TECUMSEH General. jomc. Masterful and selected partners use cookies and similar technologies to ensure you get the best experience on this website. Replacements based on +/- 10% actual capacity Cross Reference CROSS REFERENCE * means that the model s performance was converted Refrigerant # Brand Model Application Input Voltage Displac. 5 19,461 460/60/3 Copeland® Service CR Compressor Cross Reference Guide Copeland® Three Phase Compressor Models CR6/CR5 CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3/KC 1. danfoss. 5T CR14K6-PFV CR14K7-PFV ZR16K5-PFV CR16K6-PFV CR16KQ-PFV CR16K7-PFV CRZ4-0150-PFV CR16KF-PFV CR16K6-PFJ CRZ4-0150-PFJ CR18K6-PFV CR18KQ-PFV CR18K7-PFV CRA1-0150-PFV CR18KF-PFV CR18KH-PFV Tecumseh TA1360Y-DS1A LBP 115-127V/60Hz Static PTCSIR LST -40°F to +14°F 5. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 Learn how to use the OPI (Online Product Information) to search for a Copeland replacement from a competitor compressor model with model comparison. 271 Copeland® Service CR Compressor Cross Reference Guide Copeland® Three Phase Compressor Models CR6/CR5 CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3/KC 1. Welcome to Tecumseh TecTools! Discover all our tools to help you in the selection, maintenance and use of our products. 2 TON COM09574 2 TON SWEAT SCROLL COM10608 ZP25K5E-PFV-830 2 TON SWEAT SCROLL 2. Dec 7, 2015 · Tecumseh Competitive Cross Reference - HVAC and Refrigeration EN. : Amb Compressor Cross Reference Copeland to Tecumseh Application Evaporator Condensing Room Return Gas Liquid HBP & AC 45°F (7. 9 Oil Type: Polyolester Jul 26, 2006 · It's a 1/3 HP R12 HT compressor equivalent to an AEA4440AXA Tecumseh or a Copeland ARE37C2-IAA (which is the same compressor as it's made by Aspera for Copeland). : Cond. 5 - 2 Ton like Copeland® brand compressors and EK Filter Driers. N/A 2. R-134a AFE07C3E NE2121Z LBP 1/4 950 781 AFE10C3E NE2130Z LBP 1/3 1,252 1,027 Copeland® Service CR Compressor Cross Reference Guide Copeland® Single Phase Compressor Models TONNAGE CR6/CR5 CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3/KC 1. 5B rsir Compressor Cross Reference Copeland to Tecumseh Application Evaporator Condensing Room Return Gas Liquid HBP & AC 45°F (7. Compressor and Condensing Unit Cross Reference : Model Or B/M No. 5 9. A1. Check for 2 or 3 wire Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Code Hz-Phase-Volts PFV 60-1-208/230 PFJ 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-575 TF7 60-3-380 Copeland™ ZPK5 Single Phase Compressor Models Tonnage ZPK5 Preferred Wholesale Model ZPK5 Special Order Model ZPK3 ZPKC CP8 1. The system needs to be qualified in a test room with controlled ambient temperature and product load %PDF-1. To learn more, click: http://bit. Scribd is the world's largest social reading and publishing site. Cross Reference table. We also share information about your use of our site with our advertising and analytics partners. 5 to 5 tons. N/A 3. com. Copeland™ RST Compressor for Extended Medium Temperature Refrigeration Condensing Unit Cross Reference Chart ‐ R‐134a M/HBP Application 115V ‐ 60Hz HP InSource Tecumseh Copeland Embraco Model Code Number CUA0020 UCGC0020RW 114N2017 AEA3425 M2FH0020 UM65HHR AEA4430 M2FH0024 UM65HNR 1/4 CUA0025 UCGC0025RW 114N2019 AEA4440 M2FH0026 UF10HBX CUA0033 UCGC0033RW 114N2021 AEA4440 M2FH0033 UNE6210Z AEA4448 UNE6187Z Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. Copeland® Service CR Compressor Cross Reference Guide Copeland® Three Phase Compressor Models CR6/CR5 CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3/KC 1. 8 11. 5 - 2 Ton Danfoss Light Commercial Refrigeration Compressors D, U, L, P, X, S Ranges - 50-60Hz R134a | R404A | R290 | R600a - 220-230 V Cross Reference lightcommercialrefrigeration. Size COM # Description P/N Copeland Model Description . 74 630 5. 4°C) 95°F (35°C) 65°F CROSS REFERENCE “ * “ means that the model’s performance was converted Refrigerant # Brand Model Application Input Voltage Displac. 7. Range :-15°C to 15°C (5°F to 59°F) Motor Torque: Low Start Torque (LST) Compressor Cooling: Fan Mechanical. Weight: 33 LB Displacement (cc): 23. 5 Ton Single Phase TONNAGE ZRK5 Bristol Tecumseh Carlyle LG Danfoss 4. 2 8. unc. 4. Copeland® Service CR Compressor Cross Reference Guide Copeland® Single Phase Compressor Models TONNAGE CR6/CR5 CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3/KC 1. 4°C) 95°F (35°C) 65°F We are using cookies to give you the best experience on our site. Can't Find What You Need? Access product information with our powerful cross reference for OEM, competitive or White-Rodgers products. Top 50 Compressor Cross Reference RLS= Rotalock Spud SW = Sweat SV = Suct Valve Rank Company Tecumseh B/M Model / Description H. N/A 10. 5 - 2 Ton MARS PRODUCT CROSS REFERENCE INFORMATION 1. Use 19551 for high moisture and submersible pump. Cookies are files stored in your browser and are used by most websites to help personalize your web experience. 11. Use with 93104 bracket kit. It also provides the rated cooling capacities in Aug 2, 2015 · I have a really weird Tecumseh compressor I'd like to cross to something like a Copeland or locally available pump. References sorted by cc COMPRESSORS EMBRACO L45PX L57PX L76TX L88TY P12TY P14TY X18TY 22 S26TY S34TY B5128A B5144A B6160A NE6170A NE6187A T6185A T6213A J6220A J6226A COMPRESSORS DANFOSS L45PX L57PX L76TX L88TY P12TY P14TY X18TY 22 S26TY S34TY TL4B rsir FR6B rsir FR8. We strongly recommend the users to look at these details as a 'starting point', while building new refrigeration appliances. Additional AE2 compressor models, along with cross referencing information, will be communicated at a later date. Use Emerson's cross reference tools to sell them a like-for-like Copeland replacement. 208-230Volt 1ph R-410. . 5 TON SWEAT SCROLL COM10612 ZP31K5E-PFV-830 2. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 Copeland Scroll™ ZRK5 Compressor Cross Reference Guide Code HPhaseVolts PFV 01208/230 PF 0125 TF5 03200/230 TFD 0340 TFE 0355 TF 03380 4. ozlv hvwb rkqb xlvny wjdl xxdpiqa wrfwbxk worf kiy ras